From Data to Decisions.
(Sat - Thursday)
Info Text
(8am - 7pm)


From Data to Decisions. We transform precise aerial, LiDAR, and IoT data into actionable insights - empowering businesses to make confident, evidence-based decisions. Through advanced analytics and AI-driven intelligence, we help organizations across infrastructure, real estate, and industrial sectors enhance safety, optimize performance, and unlock hidden value in their assets.
© Copyright 2024 All rights reserved.
Indoor Air Quality (IAQ) is not a “comfort metric.” In building operations, it is a live indicator of ventilation performance, contaminant ingress, and safety risk-especially in basements, mechanical rooms, and low-ventilation zones.
A common mistake is reacting to single readings. The engineering approach is to quantify persistence (time-above-threshold), trend behavior, and event correlation:
CO₂ as a proxy for ventilation adequacy (baseline drift + exceedance duration)
PM2.5 / PM10 as filtration/infiltration performance signals (spikes + persistence)
VOC as a source indicator (materials/cleaners/solvents/off-gassing; sustained elevation)
Basement gas flag (0/1) as a safety event that should trigger an operational response workflow
Sensor stack (typical, zone-based)
infrascan.ai instruments IAQ by zones (basement segments, mechanical rooms, utility penetrations, corridors/lobbies) using:
NDIR CO₂ sensor → CO2 (ppm)
Optical particle sensor (laser scattering) → PM2.5 / PM10 (µg/m³)
VOC sensor (PID or MOS, application-dependent) → VOC (ppb)
Temperature / RH probe → Indoor temp (°C), RH (%) (context + condensation/mold risk)
Electrochemical gas detector (site-dependent) → Basement toxic gas (0/1) (e.g., CO / H₂S)
(Optional) Differential pressure / airflow → ventilation and infiltration diagnostics
What the live dashboard delivers
Raw time series + derived metrics: rates, persistence, exceedance counts
IAQ status: watch / warn / critical + event log
Correlation views: IAQ excursions vs ventilation cycles / weather / intrusion events
How this solves the problem operationally
Instead of periodic spot checks, teams get evidence-based triggers to:
separate chronic under-ventilation from episodic ingress,
pinpoint the zone driving complaints,
validate mitigation (filter changes, ventilation tuning, sealing, source removal),
escalate safety events with a time-stamped record.
hashtag#NYC hashtag#IndoorAirQuality hashtag#IAQ hashtag#FacilitiesManagement hashtag#PropertyManagement hashtag#SmartBuildings hashtag#BuildingOperations hashtag#IoT hashtag#Sensors hashtag#ConditionMonitoring hashtag#RiskManagement hashtag#PM25 hashtag#CO2 hashtag#VOC #infrascan.ai